OPTICAL METROLOGY / INDUSTRIAL INTEGRATION [email protected]

01 / INTEGRATED POINT MEASUREMENT

CMOS laser displacement sensors

Bring displacement measurement directly into your machine.

Specify an all-in-one CMOS laser triangulation sensor for robotic positioning, PCB warpage and height measurement. Review built-in control and direct PLC outputs for your installation.

Configure LDS-TRI ↗Request the proposed model’s CAD package ↗
LDS-TRI HOUSING REFERENCE
Black and blue point-sensor housing with a front window, top display, three buttons and rear shielded cable
Representative view. Request the selected model’s drawing and configuration.

LDS-TRI / INQUIRY CONFIGURATIONS

Choose the stand-off before the output variant.

Use these references to describe the requested geometry. They are planning identifiers, not released model specifications. The quotation must confirm the order code, achievable performance, optical arrangement and drawing.

Inquiry referenceCenter / half-span requestRequested near → farQualification neededEnquire
LDS-TRI-02525 ± 5 mm20 → 30 mm (10 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-025 ↗
LDS-TRI-03030 ± 10 mm20 → 40 mm (20 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-030 ↗
LDS-TRI-05050 ± 20 mm30 → 70 mm (40 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-050 ↗
LDS-TRI-100100 ± 40 mm60 → 140 mm (80 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-100 ↗
LDS-TRI-200200 ± 100 mm100 → 300 mm (200 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-200 ↗
LDS-TRI-400400 ± 200 mm200 → 600 mm (400 mm span)Repeatability, linearity, spot and output variant require confirmation.Use LDS-TRI-400 ↗
LDS-TRI-1000Up to 1,000 mm distance requestSpecify both limitsWorking-distance request up to 1,000 mm. Specify the near and far positions; no symmetric span is assigned.Use LDS-TRI-1000 ↗

Near/far values above are geometry arithmetic, not measured performance. Confirm linearity, repeatability, temperature drift, spot size, measuring rate, supply voltage, enclosure rating and exact connector for the selected configuration.

LASER CLASS / INDUSTRIAL ENVIRONMENT

Confirm the class and test scope of the ordered variant.

Laser label and installation

Request the actual label, classification basis and instructions for this LDS-TRI configuration. Include reflective targets, external optics, covers and setup/service access in the machine review.

Environmental and market records

Match declared ingress/temperature limits and EMC, shock or vibration evidence to the complete assembly and test conditions. Identify the destination and applicable declaration/report scope.

Class, ratings, certificates and document availability require configuration-specific confirmation. A measurement output is not a certified personnel-protection function.

INTEGRATED CONTROL / PLC OUTPUTS

Count the complete sensing chain.

A separate head, amplifier and communication module can be appropriate for a multi-channel system. For a compact machine, an integrated variant may reduce cabinet space and wiring points. Compare the complete supply scope before comparing unit prices.

Specify the required 4–20 mA, 0–10 V, RS485 Modbus or IO-Link variant. Confirm simultaneous-output behavior rather than assuming all listed signals are active together.

The Keyence IL model catalogue distinguishes sensor heads from amplifier units. It does not establish a fixed price difference or universal alternative.

Read the original IL model catalogue ↗
Example split sensor chain compared with a requested integrated sensor-to-PLC configuration
Concept architectures. Communication and output functions depend on the selected variant.

Compare the complete installation cost.

Compare two USD acquisition scopes, identify missing costs and take the worksheet to the engineering enquiry.

Open the price and scope worksheet ↗

SELECTION REVIEW / LDS-TRI

Set the acceptance conditions with the configuration.

Requested distance / field

25–1,000 mm distance requests

Performance review

Repeatability qualified per configuration

Integration choices

4–20 mA · 0–10 V · RS485 · IO-Link

These are selection envelopes. Maximum field, rate, resolution and interface functions require confirmation for the same ordered configuration.

01

Center / half-range requests: 25±5, 30±10, 50±20, 100±40, 200±100 and 400±200 mm. Specify the nearest and farthest working positions; stand-off distance is not the measurement span.

02

Ask for OLED setup, a built-in controller and the required analog or digital variant. Confirm whether outputs operate simultaneously, as well as NPN/PNP configuration and cable pinout.

03

Black rubber, polished steel and abrupt reflectivity changes need target trials at the intended exposure and speed. Record invalid readings and drift as well as averaged repeatability.

Application focus: PCB warpage · robot positioning · packaging height

Existing-family references: Keyence IL-030 / IL-065 / IL-100 / IL-300 · Micro-Epsilon optoNCDT 1320 / 1420 · SICK OD Value · Banner Q4X. Send the full suffix, drawing and integration requirements for assessment.

HARDWARE / INSTALLATION REFERENCE

Compare the display, optical window and mounting envelope.

Bring the space around the head into the configuration review, including access to controls and cable bend clearance.

Compact yellow and black point-sensor housing with a top display, three buttons and rear cable
Compact display housing
Silver point-sensor housing with two front optical windows and top display controls
Display and optical-window arrangement
Graphite sensor housing with two front windows, four top controls and side mounting holes
Two-window point-sensor housing

Representative housing views. Confirm the exact model, dimensions and supply scope. Housing color does not identify laser wavelength.

LDS-TRI / MEASURING GEOMETRY

Keep the optical path clear across the measuring field.

Use the measurement concept to define the target position and available access. Request the selected head’s calibrated field and clearance drawing.

Review the working principle ↗
CMOS laser displacement sensors conceptual measurement geometry
Concept geometry; not a dimensional drawing or measured performance record.

TWO HEADS. ONE THICKNESS.

Measure the sheet,
even when it moves.

Opposed sensors measure both surfaces at the same position and time. With a calibrated fixed gap C, the geometry is:

Thickness T = C − (A + B)

Ideal rigid-body sheet motion cancels when both readings are synchronized and aligned. Real uncertainty includes both sensors, frame expansion, calibration, tilt and timing mismatch. Lateral spot offset also matters: a 0.5 mm offset with 1° sheet tilt produces about 8.7 μm of apparent thickness change. Align the spots and verify with a master thickness.

Request a matched LDS-TRI / LDS-PRO pair, synchronized calculator and C-frame. Micron-level thickness requires validation of the complete assembly.

Opposed laser heads measure distances A and B within fixed gap C
Concept geometry, not a calibrated model drawing.

CHOOSE THE MEASURING PRINCIPLE

Small movements. Long distances.
Different optical tools.

DecisionLaser triangulationPhase-shift distance
Typical requirementShort stand-off; micron-level displacementPlant-scale travel; millimeter-level distance
How it measuresTarget spot position on a CMOS detectorPhase delay of modulated returning light
Choose forThickness, runout, height, gapStacker cranes, long travel, remote positioning
FamilyLDS-TRI / LDS-PRO; LDS-2D for profilesLDS-LNG; range depends on target
VerifySurface, angle, linearity, measuring rateReflectivity, ambient light, update rate, confidence level

Resolution, repeatability and absolute accuracy describe different properties. Request the selected configuration’s measurement conditions.

LDS-TRI / ENGINEERING HANDOFF

Request the files your design review needs.

Ask for the proposed model’s current revision. File availability, supported functions and calibration scope are confirmed during configuration review.

M12 pin count is only the first check.

Mechanical fit

Housing dimensions, optical-axis height, mounting holes, connector clearance and cable bend space.

Electrical assignment

Connector coding, supply and ground, analog reference, output polarity, load and shield termination. Request the drawing for both complete part numbers.

PLC / acquisition

Scaling, register or process-data map, units, invalid-data flags, trigger behavior, update period and the correct IODD / ESI / GSDML / EDS file where supported.

LDS-TRI / BEFORE THE DRAWING REVIEW

Resolve the questions that change the configuration.

Is the center distance the same as the measuring range?

No. A 100±40 mm request describes an 80 mm measuring span from 60 to 140 mm. These geometry values define an inquiry; the selected model’s datasheet establishes its actual ratings.

Can analog, RS485 and IO-Link all operate together?

Do not assume every listed interface operates simultaneously. Confirm the exact output variant, wiring, switching mode and communication behavior in the written configuration.

Can I replace an IL or Q4X without rewiring?

Send the complete original part number and wiring drawing. Connector pin count, mounting dimensions and similar nominal range do not establish electrical or optical interchangeability.

LDS-TRI / CONFIGURATION & DOCUMENT REQUEST

Quote the complete installation.

Industrial machine integration enquiries: include the measuring task, target, tolerance and PLC interface. No online order or payment is created by this form.

Build a measurement brief

Use your company address if available. A project contact using another email can still request a review.

An inquiry reference is not a released part specification or stock confirmation.

Dual-head differential thickness kit

2 matched point sensors + synchronized calculator + C-frame. Final optics, synchronization, uncertainty and price require a system quotation. Leave the kit unchecked for a sensor-only request or if you provide the frame and synchronization system.

Installation & optical optionsReview protection, cable, optical and display choices ↗

Opening the catalog does not save contact or project notes. Save them before leaving; your engineering selections travel with the link.

Reference budgets in USD per accessory unit, subject to compatibility and written quotation. A matched pair may need two cables or housings; quantities and unit basis are confirmed in the quote. A blue optical variant is not a field emitter swap; a display is not a synchronized high-speed controller.

Documents to request for the proposed configuration

Select what your design team needs. We will confirm document availability and revision for the proposed model; no file or qualification is implied by selecting it.

Range bands are categories. Include the exact nearest and farthest positions in your notes, especially any long-range approach below 1 m.

Your details are used to review this request. Privacy policy. For confidential drawings, ask to agree the NDA and transfer method before sending the files.

Preparing enquiry check…